MS1250
Single Point
Load Cell |
| Capacities |
50,75, 100, 150, 200, 250, 300, 500,635kg
single point load cells |
| Rated Output |
2 +/- 10% mV/V |
| Total Error |
0.02 +/-% of applied load |
| Total Error of
Off Center Loading Anywhere on a 600 x 600mm Platter meets OIML Regulations for |
2000 divisions |
| Creep at Rated Capacity: Zero return after 30
minutes |
0.025% of applied load |
| Zero Balance |
+/- 10% of rated
output |
| Operating Temperature range |
-30șC to 70șC |
| Compensated
Temperature range |
-10șC to +40șC |
| Temperature Effect on Ouput |
0.0014% of applied load/șC |
| Temperature
Effect on Zero |
0.0060% of rated
output/șC |
| Maximum Safe Moment |
30 x Rated Capacity
(to 300 kg)
10,000 (>300kg) |
| Maximum Overload
at the Center Loading Point |
200% of rated
capacity |
| Ultimate Overload at the Center Loading Point
without Mechanical Stop |
300% of rated capacity |
Excitation:
Recommended
Maximum |
10 volts
20 volts |
| Input Impedance |
415 +/- 15 ohms |
| Ouput Impedance |
350 +/- 3 ohms |
| Insulation Resistance |
>5000 megohms |
| Deflection at
Rated Capacity |
<0.4 mm |
| Weight |
2.4 kg |
| Cable |
3 meter 6 wire
polyurethane jacket dual screen (not connected to Load Cell body) |
|