Programmable
Indicators |
 |
Applications include:
Batching Control, Gravimetric Control, Truck Management, Feedback Signal Control, Custom
Machine Control, Gain in weight Systems, Bagging Systems, and Inventory Control Systems.
|
|

Dimensions are in inches and (mm). |
| A |
B |
C |
D |
E - mounting holes |
F |
G |
| 9.38 (238.3) |
8.38 (212.8) |
2.20 (55.9) |
8.00 (203.2) |
.28 (7.1) dia |
2.20 (55.9) |
9.00 (228.6) |
 |
|
PERFORMANCE |
|
|
|
100,000 displayed
+/- 500,000 internal |
|
|
|
20 conv./sec., response time
to FS selectable, 0.12 - 11 sec. |
|
 |
|
.0.005% of FS (input dependent) |
|
|
- Calibration
- PDIO Frequency Input/Output
- Frequency Voltage
- I/O Relay Scan Rate
- Program Timer Resolution
- Warranty
|
Selectable,
5 multi-point calibration
8 HZ-100 KHz
5 Vdc
16 ms maximum
2 ms
1 year |
|
|
|
|
|
|
Load Cell Input |
|
|
- Connections
- Power
- Signal Range
- Excitation
- Current
|
4 lead or 6 lead with sense, jumper
selectable
12 (twelve) 350 ohm cells
0.1 to 20 mV/V at FS
10 VDC or VAC, short circuit protected
290 mA maximum |
|
|
|
|
|
|
Electrical |
|
|
|
90-250 VAC, 50/60 Hz
0.5 amp Slow - Blow |
|
|
|
|
|
|
Communications |
|
|
- Port 1
- Port 2
- Port 3
- Port 4
- Baud Rate
|
Serial RS232 bi-directional
RS485 multidrop optional
Serial RS232 bi-directional
Serial RS232 bi-directional
Serial RS232 bi-directional, TTL
150-19200 bits/sec.
38,400 w/ RS485 multidrop
between controllers
|
|
|
|
|
|
|
I/O Specifications |
|
|
- Maximum
- Voltage Ratings
- I/O Timer Resolution
|
128 Inputs/Outputs
3 VDC - 250 VAC @ 3A
10 ms |
|