Programmable
Indicators |
 |
|
SPECIFICATIONS |
|
|
- Capacity
- Graduations
(readability)
(lb or kg)
|
5 to 10,000
(user selectable)
0.0005 to 10
(user selectable) |
|
 |
|
1:5,000 LFT or 1:20,000 max
(user selectable) |
|
|
|
lb, kg, oz, g
(user selectable)
|
|
|
|
Capacity plus 9d |
|
|
|
3 secs |
|
|
- Auto-zero tracking capture range
|
OFF, 0.5, 1 or 3 divisions
(user selectable) |
|
|
|
2%, 100% of capacity |
|
|
|
1:200,000 |
|
|
|
0º - 40ºC LFT: 10º-40ºC |
|
|
|
10% to 95%RH |
|
|
|
Push button (selectable up to
100% capacity) |
|
|
- Load cell excitation voltage
|
5 V dc |
|
|
- Load cell input sensitivity
|
1 to 3 mv/V |
|
|
|
60mA at 5 V
(drives up to four 350 ohm load cells) |
|
|
|
LCD (1.5 high) |
|
|
|
AC adaptor: 100, 120, 220, 240 V ac, 50/60Hz
or 6 alkaline 'C' batteries |
|
|
|
125 hours with one load cell
55 hours with four load cells |
|
|
|
19.1 x 15.2 x 7.6 |
|
|
|
1.2 |
|
|
|
NIST HB44 Class III and IIIL
NTEP Certificate of conformance 93-112A1 |
|